가변 주파수 드라이브를위한 고성능 랙 AHF (VFD)

소개: The Harmonic Problem in Modern VFD Systems

As industries adopt more Variable Frequency Drives (VFD) for energy efficiency and motor control, the rise in nonlinear loads introduces a serious problem—harmonic distortion. These unwanted harmonic currents reduce equipment life, increase transformer losses, and jeopardize compliance with IEEE 519 standards.

That’s where the High Performance Rack Mounted Active Harmonic Filter (AHF) comes into play—a powerful, scalable solution that neutralizes harmonics at their source.

Rack AHF for Variable Frequency Drives (VFD)

What Is a Rack-Mounted Active Harmonic Filter?

A rack-mounted AHF is a compact, modular harmonic mitigation system designed to target and cancel specific harmonic frequencies generated by VFDs and other nonlinear loads. 수동 필터와 달리, AHFs are dynamic, continuously monitoring the load and injecting inverse currents in real time.

CoEpower’s Parallel Rack Mounted AHF Module is a prime example of advanced harmonic mitigation technology, tailored for applications where flexibility, scalability, and performance are critical.

Why Choose a Rack AHF for VFD Applications?

1, Optimized for VFD Harmonics

VFDs typically generate 5th, 7th, 11th, and 13th order harmonics. CoEpower’s rack AHF dynamically cancels these frequencies, maintaining THDi (전류의 총 고조파 왜곡) well below 5%, thus ensuring IEEE 519 compliance.

2, Modular and Scalable Design

The rack design allows parallel connection of multiple modules, giving you the flexibility to scale your harmonic filtering needs based on real-world load conditions. Whether you’re running a small industrial line or a large HVAC system, the parallel rack AHF module can grow with your facility.

3, Compact Footprint, Easy Integration

The 4U rack size saves precious panel space and integrates easily into new or existing switchboards, MCCs, or control panels—ideal for retrofit or space-constrained environments.

4, Real-Time Harmonic Compensation

With fast response time and real-time waveform correction, the AHF protects sensitive electronics, reduces heating in cables and transformers, and enhances the overall reliability of your electrical system.

5, 의사소통 & Monitoring

CoEpower’s AHF supports Modbus RTU over RS-485 for easy BMS or SCADA integration, providing operators with live access to current harmonics, filter status, and load profiles.

Technical Highlights from CoEpower’s Parallel Rack AHF Module

Rated Current: 50에이, scalable to 100A, 150에이, and beyond via parallel modules

Voltage: 400V ±15%, 3-단계, 3-wire

Compensation Range: 2nd to 50th harmonic

Efficiency: ≥ 97%

응답 시간: < 100 microseconds

Colling: Intelligent air-cooled system with temperature control

Mounting: Standard 19-inch 4U rack

Benefits of Using CoEpower’s Rack AHF in VFD Installations

✅ Improved Power Factor

✅ Lower Transformer and Cable Losses

✅ Protection for Sensitive Equipment

✅ Reduced Downtime and Maintenance Costs

✅ Compliance with International Standards (IEEE 519, IEC 61000)

Applications of high-performance rack AHF:

-Industrial automation systems

-HVAC plants using VFDs

-데이터 센터

-기름 & gas facilities

-Water treatment plants

-Commercial buildings with nonlinear loads

A Future-Ready Solution for VFD Harmonics

As power systems become increasingly complex, maintaining clean power is no longer optional—it’s a necessity. If your facility relies heavily on VFDs or other nonlinear loads, investing in a rack-mounted Active Harmonic Filter, such as CoEpower’s parallel module, is the smartest move you can make for reliability, efficiency, and regulatory compliance.

태그: 랙 장착 AHF, active harmonic filter for VFD, 고조파 왜곡, IEEE 519 compliance, VFD power quality, 병렬 AHF 모듈, rack AHF module, 코퍼 ahf, 고조파 완화, 가변 주파수 드라이브.

Learn more about the Parallel Rack Mounted AHF Module by CoEpower: