현대 전기 네트워크, 특히 산업 시설에 전력을 공급하는 것, 데이터 센터, 및 상업용 건물-비선형 하중으로 생성 된 유해한 왜곡 (VFD처럼, UPS 시스템, and LED drivers) poses a significant challenge to power quality. Selecting the right harmonic mitigation strategy is key. This blog dives into Active Harmonic Filters (AHFS) versus Passive Harmonic Filters (PHF) and guides you on when to opt for each—integrating insights from CoEpower’s Active Harmonic Filter solutions.

Passive Harmonic Filters (PHF)

PHFs use traditional components—inductors, 커패시터, resistors—tuned to target specific harmonic frequencies. They’re simple and cost-effective, ideal for predictable, static systems where harmonic content doesn’t vary. But they:

-Operate only at pre-designed frequencies

-Can suffer from resonance issues

-May introduce a leading power factor when unloaded

활성 고조파 필터 (AHFS)

CoEpower’s Active Harmonic Filter solutions

AHFs represent a modern, dynamic solution. They continuously monitor harmonic disturbances using sensors and a DSP, then inject compensating currents to neutralise those harmonics in real time

Advantages include:

-Real-time adaptation to load changes

-Targeting a broad range of harmonics

-No leading power factor at low load

-Flexible installation points (e.g. at PCC or switchboards)

When to Choose a Passive Filter

가장 좋습니다:

-Single, stable harmonic sources—like a solitary VFD with a known frequency

-Budget-constrained projects—lower upfront cost; lower maintenance

-Applications with predictable loads—SCADA systems, specific motor drives, 등.

단점:

-Inflexible to changes in system load

-Risk of resonance and inefficiency under varying conditions

-Requires tuning per device—can become costly if scaled across

When to Choose an Active Filter

Ideal for:

-Complex systems with multiple, variable loads—data centers, multi-VFD plant environments

-Applications requiring ultra-low THD (e.g. IEEE-519 limits: <5–8%)—AHFs remain effective even at low load

-Centralized installations (point-of-common-coupling vs per-VFD) offering installation flexibility

-Systems needing reactive power compensation or three-phase balancing

Trade-offs:

-초기 비용이 더 높습니다

-Requires skilled planning and configuration

-Slightly higher maintenance due to electronics—but offers superior long-term performance

CoEpower’s Active Harmonic Filter: Advantages in Focus

Integrating CoEpower’s APF insights elevates this decision-making:

Dynamic Harmonic Mitigation: Leverages high-speed DSP algorithms to monitor and compensate harmonic currents in real time.

Flexible Form Factors: Offers rack-mounted, wall-mounted, and cabinet-integrated options for seamless deployment.

Fast Response & High Accuracy: Ideal for demanding applications where precision and speed are paramount.

확장 성: Modular designs facilitate easy expansion as load profiles evolve; perfect for growing operations.

Quick Comparison Table

CriteriaPassive Harmonic Filters (PHF)활성 고조파 필터 (AHFS) – CoEpower
Best Use CaseStable single-source harmonicsVariable, multi-load systems
CostLow CapEx, minimal maintenanceHigher CapEx, minimal long-term costs
AdaptabilityFixed-frequency tuning onlyReal-time, comprehensive compensation
설치At each harmonic sourceCentralized or flexible placement
PerformanceAdequate for basic THD controlSuperior across load range, even under light load
전력 계수May cause leading PFMaintains PF, sometimes improves it
Size & Modularity부피가 커집니다, per-device콤팩트, modular, scalable
CoEpower FeaturesDSP-based, multiple mounting, 빠른 응답

결론

-Passive filters shine in simple, budget-conscious, and stable environments.

-Active filters, especially CoEpower’s APFs, excel where loads fluctuate, precision matters, and future scalability is essential.

자세한 내용은 활성 고조파 필터 제품 페이지를 탐색하십시오.:

By aligning the right filter with your system’s complexity, performance needs, and infrastructure, you ensure optimal power quality, 능률, and reliability.