FAQ sur le générateur VAR statique SVG

UN Générateur VAR statique (SVG) is an advanced power quality device designed to provide real-time reactive power compensation and improve power factor. Contrairement aux banques de condensateurs traditionnels, SVG offers dynamic, stepless adjustment, ensuring stable voltage and efficient power distribution. It is widely used in industrial facilities, renewable energy systems, centres de données, and commercial buildings where power quality and stability are critical. Below are some frequently asked questions to help you understand SVG technology better.

Générateur VAR statique SVG

Q1: Qu'est-ce qu'un générateur VAR statique (SVG)?

Un générateur VAR statique (SVG) est un dispositif de qualité de puissance pour une compensation de puissance réactive dynamique. Il aide à stabiliser les niveaux de tension et à améliorer le facteur de puissance en injectant ou en absorbant la puissance réactive au besoin. Contrairement aux banques de condensateurs traditionnels, SVG fournit une compensation en temps réel et fonctionne efficacement dans des conditions de charge variables.

Q2: Comment sélectionnez-vous un générateur VAR statique?

Lors du choix d'un SVG, Considérez les facteurs suivants:

-Demande de puissance réactive: Déterminez l'évaluation KVAR requise en fonction des besoins en puissance réactive du système d'alimentation.

-Type de chargement: Convient aux industries avec des demandes de pouvoir réactives fluctuantes, comme le soudage, centres de données, et les plantes en acier.

-Temps de réponse: Recherchez des temps de réponse rapides (typiquement <5MS) Pour gérer les charges dynamiques.

-Tension et capacité du système: Assurer la compatibilité avec l'infrastructure électrique existante.

-Environnement d'installation: Considérez les installations intérieures ou extérieures et les facteurs environnementaux comme la température et l'humidité.

Q3: Quelle est la différence entre un générateur VAR statique et une banque de condensateurs?

SVG: Utilise une électronique de puissance avancée (Technologie basée sur IGBT) Pour une rémunération réactive en temps réel, fournir des, Contrôle sans pas.

Banque condensateur: Utilise des condensateurs fixes ou commutés pour compenser la puissance réactive en étapes discrètes, ce qui peut conduire à une surcompensation ou à une sous-comparaison.

Q4: Quelle est la différence entre un SVG (Générateur VAR statique) Et un ahf (Filtre harmonique actif)?

FonctionnalitéSVG (Générateur VAR statique)Ahf (Filtre harmonique actif)
Fonction primaireCompensation de puissance réactive (Correction du facteur de puissance)Compensation harmonique & Correction du facteur de puissance
Avantage cléStabilité de tension, facteur de puissance amélioréRéduction de la distorsion harmonique
Mieux pourCorrection du facteur de puissance & stabilité de tensionEnvironnements riches en harmonique (VFDS, Hauts, charges non linéaires)
TechnologieRémunération en temps réel basé sur IGBTFiltrage harmonique en temps réel basé sur IGBT
Vitesse de réponse<5MS<1MS
Effet sur les harmoniquesN'élimine pas les harmoniquesAnnule activement les harmoniques

SVG est idéal pour la stabilité de la tension et le contrôle de la puissance réactive.

AHF est meilleur pour les environnements riches en harmonique et l'amélioration de la qualité de l'énergie.

Pour des solutions complètes de qualité d'énergie, SVG et AHF peuvent être utilisés ensemble dans des systèmes électriques complexes.

Q5: SVG est-il adapté à tous les types de charges?

SVG est idéal pour les charges dynamiques qui nécessitent une compensation de puissance réactive et une correction du facteur de puissance, y compris:

Équipement de soudage (Machines de soudage à l'arc, Machines de soudage à la résistance)

Ascenseurs, grues (Changement rapide des charges)

Systèmes d'énergie renouvelable (énergie éolienne, PV solaire)

Applications industrielles (acier, chimique, industries du ciment)

Centres de données, hôpitaux, aéroports (Exigences de qualité élevée)
Cependant, SVG a des effets limités sur les charges résistives pures (Par exemple, radiateurs électriques).

Q6: SVG sera-t-il en conflit avec AHF (Filtre harmonique actif)?

Non, SVG et AHF peuvent travailler ensemble pour améliorer la qualité globale de l'énergie:

SVG se concentre sur la compensation réactive de puissance et l'amélioration du facteur de puissance.

AHF élimine les harmoniques et réduit la distorsion harmonique totale (THD).

L'utilisation des deux en combinaison est idéale pour les environnements avec des charges non linéaires telles que les VFD, Hauts, et fours à arc électrique.

Q7: What is the difference between STATCOM and Static Var Generator?

STATCOM (Static Synchronous Compensator) and SVG operate on similar principles, both using IGBT-based technology for fast and precise reactive power compensation.

Key difference: STATCOMs are used in high-voltage transmission systems, while SVGs are more common in low- to medium-voltage industrial and commercial applications.

Q8: How fast is the response time of SVG?

Modern SVGs use IGBT (Transistor bipolaire de porte isolée) technologie, with response times of ≤5ms, much faster than traditional thyristor-switched capacitor (TSC) or Static Var Compensator (SVC) systems, making them suitable for rapidly changing reactive power demands.

Q9: What is the difference between SVG and TSC (Thyristor-Switched Capacitor)?

FonctionnalitéSVG (Générateur VAR statique)TSC (Thyristor-Switched Capacitor)
Control MethodIGBT electronic control, real-time dynamic adjustmentThyristor switching, step-based compensation
Compensation AccuracyContinuous, high precision (stepless adjustment)Discrete capacitor steps, lower precision
Response Time≤5ms (very fast)10ms-1s (slower)
Harmonic EffectsDoes not generate harmonics, can help mitigate themMay cause resonance with system harmonics
Mieux pourDynamic loads (welders, ascenseurs, etc.)Stable loads with moderate changes
Lifespan & MaintenanceElectronic components, long lifespan, low maintenanceMechanical switching wears out faster, rand equires more maintenance

SVG is recommended for rapidly changing loads, while TSC is better for more stable load conditions. They can also be used together for optimal performance.

Q10: Can SVG be used in renewable energy systems (solar/wind)?

Oui, SVG is widely used in wind power, PV solaire, and energy storage systems, providing benefits such as:

Reactive power compensation to improve power factor, ensuring compliance with grid standards (Par exemple, IEEE-519).

Balancing three-phase currents, reducing grid instability.

Minimizing voltage fluctuations and flicker, particularly in wind and solar systems with variable power output.

Q11: Does SVG help with energy savings?

SVG does not directly save energy, but it can reduce power losses, leading to indirect cost savings by:

Improving power factor, avoiding penalties for reactive power usage.

Reducing line losses, and decreasing the load on transformers, cables, and switchgear.

Stabilizing voltage, enhancing equipment efficiency and lifespan.

Q12: How to determine the required capacity of an SVG?

The required SVG capacity (kVAR) depends on the reactive power demand of the system. General guidelines:

Measure the system’s reactive power requirement (kVAR).

Select an SVG with a rating slightly higher than the peak reactive demand to prevent under-compensation.

In complex load environments, distributed compensation (multiple SVG units) may be more effective.

Q13: Can multiple SVGs be connected in parallel?

Oui, SVGs support modular parallel operation, allowing for flexible expansion as power demands grow. Example applications:

Scaling up capacity by adding more SVG units.

Distributed installation in different electrical branches to optimize compensation efficiency.

Q14: Where should SVG be installed?

SVG should be installed as close to the load as possible to maximize compensation efficiency. Typical installation locations:

At substations or distribution panels (centralized compensation).

Near production areas or load centers (decentralized compensation).

Close to specific equipment (comme VFDS, ascenseurs, welding machines).

Q15: What is the lifespan and maintenance requirement of SVG?

SVGs primarily use electronic components, with an expected lifespan of 15-20 années, significantly longer than traditional capacitor banks.

Maintenance includes periodic cooling system checks, dust cleaning, and monitoring operational status, but overall maintenance is minimal.

Q16: What is the return on investment (ROI) for SVG?

SVGs help reduce power losses, improve power factor, and avoid penalties, leading to an ROI of 1-3 années, depending on:

Electricity tariffs and power factor penalty policies.

Cost savings from reduced reactive power charges.

Lower maintenance and extended equipment lifespan.

Q17: In which industries is SVG most beneficial?

SVG is ideal for industries with dynamic loads, fluctuating power factors, or high reactive power demand, tel que:
✅ VFDs, large motors, centres de données, acier, chemical plants
✅ Welders, ascenseurs, grues, port equipment
✅ Solar PV, énergie éolienne, energy storage systems

SVG can be used alone or combined with AHF, TSC, or SVC to provide a comprehensive power quality solution.

Balises: dynamic reactive power compensation, power quality device, Générateur VAR statique SVG, Banque condensateur.

Produit connexe:

Partagez le message:

Related Posts

Mettre à jour les préférences des cookies

Demandez un devis rapide

Nous vous contacterons à l'intérieur 1 jour de travail, Veuillez faire attention à l'e-mail avec le suffixe «Sales@coepower.com».